CN
Home » News » Industry News » Aircraft air vehicle safety protection and emergency measures

Aircraft air vehicle safety protection and emergency measures

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button

Aircraft air  vehicle safety protection and emergency measures

1. Protection of aircraft:

Mechanical pressure relief valve

When the gas supply system pressure exceeds 50psi, the safety valve operates and deflates to maintain the system gas supply pressure.

Air supply pressure protection switch

When the pressure of the gas supply system exceeds 44psi, the pressure switch acts to implement the gas supply protection.

Unit protection cut off in starting mode

When the "select switch" on the operating panel is pressed to the "Aircraft Start" position, all protective functions of the unit are removed.

Aircraft air supply connection with screen

2. Protection of the unit:

High engine water temperature protection

When the coolant temperature in the radiator exceeds 103 ° C, the unit automatically stops, and the engine water temperature indicator on the operation panel lights up.

Low engine oil pressure protection

When the engine oil pressure is lower than 270kPa, the unit will automatically stop, and the engine oil pressure low indicator on the operation panel will light up.

Engine cooling low level protection

When the engine coolant level is low, the unit automatically stops and the coolant level low indicator on the operation panel lights up.

Compressor oil temperature high protection

When the compressor oil temperature exceeds 76 ° C, the unit automatically stops, and the compressor oil temperature indicator on the operation panel lights up.

Low compressor oil pressure protection

When the compressor oil pressure is lower than 50kPa, the unit automatically stops, and the compressor oil low pressure indicator on the operation panel is on.

High protection of compressor gas supply temperature

When the air supply temperature of the compressor is higher than 220 ° C, the unit automatically stops, and the high air supply temperature indicator on the operation panel lights up.

Charge protection

When the charging system fails, the charging protection indicator on the operation panel lights up.

Emergency shutdown

There is an emergency stop button on the operation panel. When there is an emergency, press the button to forcibly shut down the engine.


Aircraft air source vehicle safety protection and emergency measures


Relation

Navigation

Contact Us

Jiangsu Tianyi Aviation Industry Co., Ltd.
 
Factory: No.2 Hang Kong Road High-tech zone, Jianhu county, Yancheng City, Jiangsu Province, P.R.China
 
Shanghai Office: Room 1103, Building 35, No. 1399 Jiasong Middle Road, Qingpu District, Shanghai, China
 
Tel: +86 21 50496068  /  +86 21 50496058  /  +86 400 9980 919
Mobile: +86-137 6133 5725 (As WeChat)
             +86-195 1652 8308
             +86-189 6407 9542
E-mail: joinsun@jstianyi.com.cn
             airport.gse@jstianyi.com.cn
Copyright © Jiangsu Tianyi Aviation Industry Co., Ltd. All Rights Reserved. Sitemap